top of page

Laser device for the treatment of joints, pain, stimulation of deep tissue recovery and regeneration

  • Photothermal effect - Increases temperature and pressure in a controlled and safe manner
  • Photomechanical effect - Pressure waves are created that stimulate the outflow of lymph in depth
  • Photochemical effect - Major biochemical reactions occur more rapidly

Hiro 3.0 HILT

  • Detailed product description

    Features of HIRO 3.0

    HIRO 3.0 is a complete Hilterapia device including two types of attachments for different effects for effective treatment of muscle pathologies, analgesic, anti-inflammatory and anti-edema effects, effective deep into tissues.

    HIRO 3.0 promotes regenerative and regenerative processes, thereby providing effective treatment for insertion pathologies and osteoarthritis

    Three effects at the same time:

    • Photomechanical effect - pressure waves are created, which stimulate the outflow of lymph deep into the tissues. This deep massage allows rapid reabsorption of inflammatory signals and accumulated fluids. Thus, pain is quickly eliminated;
    • Photochemical effect - basic biochemical reactions occur more quickly. The readily available energy is quickly absorbed by metabolic substrates. The state of cellular balance is restored, which were violated due to pathological processes;
    • Photothermal effect - increases temperature and pressure in a controlled and safe way. The effect of beneficial circulation is enhanced, which leads to an increase in the stimulating effect and the absorption of oxygen and nutrients by damaged structures. Thus, optimal conditions are created for the treatment of pathology in a shorter time.

    Benefits of HIRO 3.0:

    • High radiation power;
    • Works effectively in deep tissue;
    • Fast analgesic effect and safety guarantee;
    • Controlled energy consumption;
    • Automatic calculation of the released energy;
    • Time tracking of thermal tissue rest;
    • User interface in Russified with touch screen, storage of the treatment protocol, personalization of therapy.

    Indication of HIRO 3.0:

    • Arthrosis and degenerative processes of cartilage
    • Bursitis, arthritis, capsulitis, epicondylitis, contusion, tendonitis, and tenosynovitis
    • Swelling and bruising due to trauma
    • Post-traumatic and post-overload disorders

    Specifications

    • Pulsed high-power Nd: YAG laser, peak power: 3 KW;
    • Pulse energy (max): 350 MJ, average power: 10.5 W;
    • Wavelength: 1064 nm;
    • Integral flux density: 1780 MJ / cm2;
    • Pulse duration: <120 μs;
    • Automatic calculation of the released energy in accordance with the specified parameters;
    • Dimensions and weight: 30 x 70 x 78 cm, 40 kg;
    • Energy consumption: 230 V, 50-60 Hz, 1840 VA.

©2007-2024 Göttmann Engineering GmbH. All Rights Reserved